Composite insulator requirement for metal accessories

by:Mings     2020-05-10
The requirements of the composite insulator to metal accessories metal accessories is an important component of the composite insulator, used to connected to the Eiffel Tower or the conductor. Composite insulator metal attachment generally use galvanized steel and must have the appropriate extensibility to connected to the mandrel. Technical requirements, test methods and inspection rules must be symbol of JB/T 8178 and the relevant provisions of the JB/T 9677. In addition to the stainless steel of all iron metal accessories should be in accordance with JB/T 8177 'insulator metal accessories galvanizing layer general technical conditions' for hot dip galvanized. Composite insulator metal accessories all the surface should be smooth, no sharp corners, burrs or irregularity case caused by corona. Such as forging shall be no cracks, thin layer, scar, wrinkled skin, silver, etc. Before the end fittings galvanized, all burrs are carefully removed, does not reduce component size, accord with a standard to ask. Under the condition of normal operation, metal accessories visible corona voltage should be within the allowable values. Composite insulator metal attachment size should comply with the provisions of GB/T 4056. Insulator installation equalizing device according to design requirements, the equalizing device materials should be used aluminum or aluminum alloy. Locking pin the insulator of steel and steel composite insulator cap connection should be equipped with reliable open rack locking device, 220 kv and above should be R ( Hunchback) Pin. Locking pin should be able to maintain in the position of locking and loosening, and should be the end of the two separate to prevent it from inside the steel cap out completely. Composite insulator locking pin should accord with the requirement of JB/T 8181. Locking pin should be used in austenitic stainless steel, brass, tin bronze corrosion resistance or other materials, anti-corrosion surface is should not be used and itself is not corrosion resistant materials, complete supply and insulator. In separate the end of the locking pin to 180 degrees, and then back to its original position in the visual inspection should not appear crack. Composite insulator assembling composite insulator metal accessories connection with mandrel pressure welding processing should be adopted, Crimping process) Make the metal accessories mechanical load evenly transfer to the mandrel. Composite insulator metal accessories and sheath should be * * sealed, the connection between the atmosphere and the isolation of must take special seal structure of special processing, in order to effectively prevent moisture and impurities to enter for a long time. Its permeability test should comply with GB/T 19519 7. Article 4 and 5. 3, 5. The provisions of article 4. Composite insulator metal accessories connect the design shall ensure that the ideal stress distribution. Crimping process acoustic emission detection method must be used with other effective means of quality control tests, put an end to end connection overvoltage and undervoltage problems. Pressure after processing of galvanized layer metal accessories in accordance with the JB/T 8177 insulator metal accessories galvanizing layer general technical conditions, and pressure welding parts ( Including pressure and border areas) The galvanized layer can not have defects such as peeling, delamination, crack or zinc. Such as pressure or move hardware, mandrel outsourcing materials, performance, size, appearance and processing technology should be strictly management and into the factory inspection. When outsourcing is not the same, must be test and destruction test ( Including pressure welding parts autopsy) New * better suppress procedures and control parameters, and the final validation report ( Autopsy color photo attached) 。 Insulator metal accessories can according to the operating pressure to reinforce the original record to track quality. Long-term preservation of records should be documented. Mark each insulator should mark factory name or trademark, manufacturing date, rated voltage, rated mechanical load and the product serial number. Mark card should adopt anaglyph moulded or with more good manufacturing process. FXBW3 - Parameter table type insulator rated voltage 35/70 KV rated mechanical tensile load KN structure height mm mm * * small arc distance small mm nominal creepage distance lightning impulse withstand voltage wave all KV≥ A minute wet resistance power frequency voltage KV≥ 35 70 ≤ 940 700 ≥ 2100 410 185 FXBW3 - Parameter table type insulator rated voltage 66/70 KV rated mechanical tensile load KN structure height mm mm * * small arc distance small mm nominal creepage distance lightning impulse withstand voltage wave all KV≥ A minute wet resistance power frequency voltage KV≥ 35 70 ≤ 870 700 ≥ 2100, 410, 185' On a message: bad weather the harm of high pressure on transmission line insulator 】 【 Next message: composite insulator to the insulating sheath, an umbrella skirt material requirements 】
Mings Electricity Technology (Dongguan) Ltd. also discusses implications for both research and the practice of operations in building systems to help people succeed in both the short and long run.
For details on power transmission product, see Mings Electricity Technology (Dongguan) Ltd. at Mings Electricity Technology.
So, what's a manufacturer to do? Familiarize ourselves with producing power transmission product in various technologies.
A quality monitoring group created for ensuring that Mings Electricity Technology (Dongguan) Ltd. manufactures power transmission product accoording the strictest standard.
The best way of power distribution solutions is to get a power distribution solutions power transmission product.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...