Railway wrist arm insulator
Model | Rated Voltage | Min Tension Failing Load | Min Ben Failing Load | Min Sliding Load | Section Length | Insulating Length | Shed Diameters | Minimum Creepage | Full-Wave Impulse Withstand Voltage (Peak) | 1 Min Dry Power Frequency Withstand Voltage | 1 Min Wet Power Frequency Withstand Voltage | Tube Hole Size |
| kV | kN | kN | kN | H | h | D | mm | ≥ | ≥ | ≥ | C |
mm | mm | mm | kV | kV | kV | mm | ||||||
FQB-25/8 | 25 | 80 | 8 | 20 | 760±20 | 490 | 165 | 1200 | 270 | 160 | 130 | 51, 62 |
FQBJ-25/8 | 25 | 80 | 8 | 20 | 760±20 | 490 | 165 | 1400 | 290 | 175 | 140 | 51, 62 |
FQBG-25/8 | 25 | 80 | 8 | 20 | 800±20 | 520 | 165 | 1600 | 310 | 190 | 150 | 51, 62 |
FQB-25/12 | 25 | 100 | 12 | 25 | 760±20 | 490 | 180 | 1200 | 270 | 160 | 130 | 62, 72 |
FQBJ-25/12 | 25 | 100 | 12 | 25 | 760±20 | 490 | 180 | 1400 | 290 | 175 | 140 | 62, 72 |
FQBG-25/12 | 25 | 100 | 12 | 25 | 800±20 | 520 | 180 | 1600 | 310 | 190 | 150 | 62, 72 |
FQB-25/16 | 25 | 120 | 16 | 40 | 800±20 | 490 | 192 | 1200 | 270 | 160 | 130 | 62, 72 |
FQBJ-25/16 | 25 | 120 | 16 | 40 | 800±20 | 520 | 192 | 1400 | 290 | 175 | 140 | 62, 72 |
FQBG-25/16 | 25 | 120 | 16 | 40 | 800±20 | 520 | 192 | 1600 | 310 | 190 | 150 | 62, 72 |
FQBJ-25/20 | 25 | 140 | 20 | 40 | 800±20 | 500 | 202 | 1400 | 290 | 175 | 140 | 62, 72 |
FQBG-25/20 | 25 | 140 | 20 | 40 | 800±20 | 500 | 202 | 1600 | 310 | 190 | 150 | 62, 72 |
Model | Rated Voltage | Min Tension Failing Load | Min Ben Failing Load | Min Sliding Load | Section Length | Insulating Length | Shed Diameters | Minimum Creepage | Full-Wave Impulse Withstand Voltage (Peak) | 1 Min Dry Power Frequency Withstand Voltage | 1 Min Wet Power Frequency Withstand Voltage | Tube Hole Size |
| kV | kN | kN | kN | H | h | D | mm | ≥ | ≥ | ≥ | C |
mm | mm | mm | kV | kV | kV | mm | ||||||
FQBS-25/8 | 3-25 | 80 | 8 | 20 | 850±20 | 490/60 | 165 | 1200/145 | 270/50 | 160/30 | 130/23 | 51, 62 |
FQBSJ-25/8 | 3-25 | 80 | 8 | 20 | 850±20 | 490/60 | 165 | 1400/145 | 270/50 | 175/30 | 140/23 | 51, 62 |
FQBSG-25/8 | 3-25 | 80 | 8 | 20 | 890±20 | 520/60 | 165 | 1600/145 | 310/50 | 190/30 | 150/23 | 51, 62 |
FQBS-25/12 | 3-25 | 100 | 12 | 25 | 850±20 | 490/60 | 180 | 1200/145 | 270/50 | 160/30 | 130/23 | 62, 72 |
FQBSJ-25/12 | 3-25 | 100 | 12 | 25 | 850±20 | 490/60 | 180 | 1400/145 | 270/50 | 175/30 | 140/23 | 62, 72 |
FQBSG-25/12 | 3-25 | 100 | 12 | 25 | 890±20 | 520/60 | 180 | 1600/145 | 310/50 | 190/30 | 150/23 | 62, 72 |
FQBS-25/16 | 3-25 | 120 | 16 | 40 | 890±20 | 490/60 | 192 | 1200/145 | 270/50 | 160/30 | 130/23 | 62, 72 |
FQBSJ-25/16 | 3-25 | 120 | 16 | 40 | 890±20 | 520/60 | 192 | 1400/145 | 270/50 | 175/30 | 140/23 | 62, 72 |
FQBSG-25/16 | 3-25 | 120 | 16 | 40 | 890±20 | 520/60 | 192 | 1600/145 | 310/50 | 190/30 | 150/23 | 62, 72 |
FQBSJ-25/20 | 3-25 | 140 | 20 | 40 | 890±20 | 500/60 | 202 | 1600/145 | 270/50 | 175/30 | 140/23 | 62, 72 |
FQBSG-25/20 | 3-25 | 140 | 20 | 40 | 890±20 | 500/60 | 202 | 1600/145 | 310/50 | 190/30 | 150/23 | 62, 72 |
Railway Tensile Insulator
Model | Rated Voltage | Specified Cantilever Load | Section Length | Insulating Length | Shed Diameters | Minimum Creepage | Full-Wave Impulse Withstand Voltage (Peak) | 1 Min Dry Power Frequency Withstand Voltage | 1 Min Wet Power Frequency Withstand Voltage |
| kV | kN | H | h | D | L | ≥ | ≥ | ≥ |
mm | mm | mm | mm | kV | kV | kV | |||
FQX-25/70, 100, 120-QH | 25 | 70, 100, 120 | 700± 20 | 500 | 145 | 1200 | 270 | 160 | 130 |
FQXJ-25/70, 100, 120-QH | 25 | 70, 100, 120 | 750± 20 | 550 | 145 | 1400 | 290 | 175 | 140 |
FQXG-25/70, 100, 120-QH | 25 | 70, 100, 120 | 800± 20 | 600 | 145 | 1600 | 310 | 190 | 150 |
FQX-25/160-QH | 25 | 160 | 750± 20 | 500 | 100 | 1200 | 270 | 160 | 130 |
FQXJ-25/160-QH | 25 | 160 | 800± 20 | 550 | 100 | 1400 | 290 | 175 | 140 |
FQXG-25/160-QH | 25 | 160 | 850± 20 | 600 | 100 | 1600 | 310 | 190 | 150 |
FQX-25/200-QH | 25 | 200 | 750± 20 | 500 | 100 | 1200 | 270 | 160 | 130 |
FQXJ-25/200-QH | 25 | 200 | 800± 20 | 550 | 100 | 140 | 290 | 175 | 140 |
FQXG-25/200-QH | 25 | 200 | 850± 20 | 600 | 100 | 1600 | 310 | 190 | 150 |
Model | Rated Voltage | Tension Failing Load | Section Length | Insulating Length | Shed Diameters | Minimum Creepage | Full-Wave Impulse Withstand Voltage (Peak) | 1 Min Dry Power Frequency Withstand Voltage | 1 Min Wet Power Frequency Withstand Voltage |
| kV | kN | H | h | D | L | ≥ | ≥ | ≥ |
mm | mm | mm | mm | kV | kV | kV | |||
FQXS-25/70, 100, 120-QH | 25 | 70, 100, 120 | 790± 20 | 500/60 | 145 | 1200/145 | 270/50 | 160/30 | 130/23 |
FQXSJ-25/70, 100, 120-QH | 25 | 70, 100, 120 | 840± 20 | 550/60 | 145 | 1400/145 | 290/50 | 175/30 | 140/23 |
FQXSG-25/70, 100, 120-QH | 25 | 70, 100, 120 | 890± 20 | 600/60 | 145 | 1600/145 | 310/50 | 190/30 | 150/23 |
FQXS-25/160-QH | 25 | 160 | 840± 20 | 500/56 | 100 | 1200/145 | 270/50 | 160/30 | 130/23 |
FQXSJ-25/160-QH | 25 | 160 | 890± 20 | 550/56 | 100 | 1400/145 | 290/50 | 175/30 | 140/23 |
FQXSG-25/160-QH | 25 | 160 | 940± 20 | 600/56 | 100 | 1600/145 | 310/50 | 190/30 | 150/23 |
FQXS-25/200-QH | 25 | 200 | 840± 20 | 500/56 | 100 | 1200/145 | 270/50 | 160/30 | 130/23 |
FQXSJ-25/200-QH | 25 | 200 | 890± 20 | 550/56 | 100 | 1400/145 | 290/50 | 175/30 | 140/23 |
FQXSG-25/200-QH | 25 | 200 | 940± 20 | 600/56 | 100 | 1600/145 | 310/50 | 190/30 | 150/23 |
Mings Electricity Technology (Dongguan) Ltd. is conveniently situated in Dongguan, Guangdong Province of China – a world-renowned city for manufacturing.
1-Incoming inspection
2-Material processing
3-Injection
4-Crimping
5-Appearance treatment
6-Mechanical performance testing
7-Electrical performance testing
8-Railway polymer insulator 3-25KV
Materials of railway polymer insulator
◪ Silicon Rubber for sheds/housing.
◪ Glass-fiber reinforced epoxy resin rod (ECR type) for core.
◪ Hot dip galvanized cast steel for metal fittings.
◪ 5000hours aging test from STRI Sweden & Prototype Test & Type Test & Factory Test ( Routine and Sampling Test ).
◪ IEC / ANSI / GB standard.
Mings has R&D and operations teams that consist of a group of elite experts, scholars, researchers, and experienced professionals who are influential in
both domestic and international power transmission and distribution industry.
The transportation and installation of the insulator shall be taken good care without any throwing or collision ,fiction with various sundries(wires,iron plates and tools etc.)and solid material.
When suspending the composite insulator,the knot shall be made on the attachment at the end.Knots on shed or sheath are strictly prohibted.When the rope has to be contacted with the shed or sheath,
the contacting area shall be pached with soft cloths.
Never apply the composite insulator as the assistant tool for the wire distribution and collection and collection in case that the insulator can be damages by impact or bending moment.
Do not step on the insulator shed with foot.
When installing the grading ring,attention shall be attached on the adjustments to make sure that the ring is vertical with the axial of the insulator.
And for opening grading ring,the opening directions at both ends shall be consistent to facilitate the discharging and protect the shed.
The company is committed to sharing expertise and technology with the Belt and Road countries and providing them with
comprehensive power transmission and distribution solutions to achieve mutually beneficial development.
Mings is dedicated to establishing a top platform for electricity & power transmission and distribution solutions,
with the purpose of better serving the Belt and Road countries’ infrastructure construction and development strategy.
Copyright © 2019 Mings Electricity Technology (Dongguan) Ltd. | All Rights Reserved
Hello, please leave your name and email here before chat online so that we won't miss your message and contact you smoothly.