Power cuts cleaning work dangerous point and its preventive measures - in detail Single loop cleaning the insulator considerations, loop clean insulator pay attention to the matter

by:Mings     2020-05-19
Job content hazard control measures to develop on the basis of a single loop 1 clean insulator. Falling 1. 1 wear a good helmet before climbing tower, pay attention to check whether the shackles is solid and reliable, and, when working on the tower must fasten your seat belt. 1. 2 belts should wear on the solid component, should prevent belts cuts from sharp objects. After wearing a seatbelt must check whether the retaining ring is fastened up. Transfer the job position of the tower and not be lose their seat belt protection. Tower on someone at work, are not allowed to change or remove the thread 2. Miss deng charged equipment 2 neighborhood. 1 before cleaning the insulator, working controller to indicate the outage operation range and hand over to treat nearby with electrical equipment and wiring. 2. 2 DengGanDa ago, to a power outage name, tower, check by wearing tag color and power lines is the same color code. 2. 3 when cleaning the insulator, * want to hang up first little ground. 2. 4 when cleaning the insulator by 2 or more persons, ready to care each other. Two more than 1 power loop time cleaning the insulator. Falling 1. 1 should wear a good helmet before climbing tower, pay attention to check whether the shackles is solid and reliable; Working on the tower must fasten your seat belt. 1. 2 seatbelt fasten on the solid component of tower, prevent stress after emergence or cut by sharp objects, seat belt buckle wants firm, tower on the transfer job position shall not lose the seat belt protection. 2. Get an electric shock 2 wrong position. 1 to indicate a power outage, head of the work scope, hand over to treat live line. 2. 2 guardianship by designated personnel. 2. 3 before cleaning the insulator personnel DengGanDa to blackout name, tower, and check with the tag color and power line colour match, climbing tower with a charged conductor is to keep a safe distance. 2. 4 on tower cleaning, are strictly prohibited to charged side of the cross arm, or any object is placed on the cross arm side. 2. Above level 5 in the wind, when cleaning the insulator is prohibited. Three resistance to a single string, linear series, hanging string coated silicone oil 1. Falling 1. 1 should wear a good helmet before climbing tower, pay attention to check whether the shackles is solid and reliable, and clean the insulator on tower, must fasten your seat belt. 1. 2 belts should wear on the solid component, should prevent belts cuts from sharp objects. After wearing a seatbelt must check whether the retaining ring is fastened up. Transfer the job position on tower, seat belt protection shall not be lost. Tower on someone at work, are not allowed to adjust or remove the cord. 1. 3 gangway logoff besmear to brush should be adopted and hang up the ground. Four double string coated silicone oil resistant 1. Falling 1. 1 should wear safety helmet before climbing tower, pay attention to check whether the shackles is solid and reliable, and before cleaning the insulator on the tower, must fasten your seat belt. 1. 2 when cleaning the insulator, first from the cross arm side to wire side cleaning, lubricating, from side to cross arm side wire brushing. Five jumper even board and groove clamp to open check 1. Falling 1. 1 climbing perch, pay attention to check whether the shackles is solid and reliable, and clean the insulator on tower, must fasten your seat belt, wearing a helmet. 1. 2 belts should wear on the solid component, should prevent the belt from the peak emergence or cut by sharp objects, fasten your seat belt, must check whether the retaining ring is fastened up. Poles on the transfer job position shall not lose the seat belt protection. 2. Elastic bolts hurt 2. 1 with nut wrench open plane to clamp, pull slowly expiratory. 【 On a message: the characteristics of silicone rubber composite insulator, composite insulator, the advantages of the silicone rubber composite insulator performance 】 【 The next message: the three major factors effecting the reliability of insulator 】
power transmission product power distribution solutions, as the name suggests, find extensive use in power distribution solutions institutions. Since power distribution solutions has become much dependent on technology in today's world, there is wide use of such power transmission product.
Crazy about products? Mings Electricity Technology (Dongguan) Ltd. is the place you must shop at, do visit Mings Electricity Technology to check out our latest collections!
Depending on the scale of the service, Mings Electricity Technology (Dongguan) Ltd. might also need to hire and manage an overseas workforce and comply with regulatory requirements.
For optimal power distribution solutions, choose a high-quality power transmission product system and make sure a certified installer sets it up.
power transmission product is receiving a great positive feedback in the market. And many of our clients are fully satisfied with it.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...